Monitoramento inteligente de bombas de infusão em unidades de terapia intensiva para adultos

Autores

  • Mario Andrés Narváez-Martínez Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.  https://orcid.org/0000-0002-4941-6918
    • Andrea Rosas-Santana Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.  https://orcid.org/0009-0001-6755-955X
      • Yudy Andrea Rojas-Castañeda Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 
        • Diana Catalina Zapata-Cristancho Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.  https://orcid.org/0000-0002-6004-1176

          DOI:

          https://doi.org/10.15649/cuidarte.5160

          Palavras-chave:

          Administração de Tratamento Farmacológico, Bombas de Infusão, Segurança do Paciente, Interoperabilidade da Informação em Saúde, Enfermagem de Cuidados Críticos

          Resumo

          Introdução: A administração de medicamentos em unidades de terapia intensiva é uma das principais atividades assistenciais dos profissionais de enfermagem. A integração do conhecimento científico, aliada ao uso de tecnologias como bombas de infusão, permite reduzir erros e melhorar a qualidade do cuidado. Objetivo:   Descrever o uso de uma plataforma de monitoramento de bombas de infusão na administração de medicamentos em unidades de terapia intensiva para adultos de um Hospital Universitário em Bogotá, Colômbia. Materiais e Métodos: Este foi um estudo retrospectivo e observacional que coletou 35.738 registros de administração de medicamentos em cinco unidades de terapia intensiva por meio do uso de uma plataforma de monitoramento durante o ano de 2023. Foi realizada uma análise descritiva utilizando frequências e proporções, bem como associações simples de adesão entre medicamentos e doses. Resultados: A adesão à biblioteca de medicamentos durante o primeiro ano de uso da plataforma foi de 66%. A plataforma relatou 5.589 recalls de medicamentos de alto risco, 76% dos quais relacionados à administração de norepinefrina, midazolam e fentanil.  Discussão: Os resultados foram consistentes com outros estudos, demonstrando adesão da biblioteca de medicamentos entre 65% e 80% no primeiro ano de implementação. Conclusão: A implementação de programas institucionais de monitoramento da administração de medicamentos, utilizando tecnologias integradas a bombas de infusão, pode impactar positivamente a segurança do paciente, reduzir os custos associados ao cuidado e fortalecer a melhoria contínua nas instituições.

          Como citar este artigo: Narváez-Martínez Mario Andrés, Rosas-Santana Andrea, Rojas-Castañeda Yudy Andrea, Zapata-Cristancho Diana Catalina. Seguimiento a bombas de infusión inteligentes en unidades de cuidado intensivo adulto. Revista Cuidarte. 2026;17(1):e5160.  https://doi.org/10.15649/cuidarte.5160

           

          Biografia do Autor

          • Mario Andrés Narváez-Martínez, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

            Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

          • Andrea Rosas-Santana, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

            Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

          • Yudy Andrea Rojas-Castañeda, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

            Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

          • Diana Catalina Zapata-Cristancho, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

            Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia. 

          Referências

          Michalek C, Carson SL. Implementing barcode medication administration and smart infusion pumps is just the beginning of the safety journey to prevent administration errors. Farmcia Hosp. 2020;44(3):114-21. http://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S1130-63432020000300008&lng=es

          Vanderveen T, O’Neill S, Beard JW. How Can We Tell How “Smart” Our Infusion Pumps Are? Anesthesia Patient Safety Foundation. 2020;35(1):21-22. https://www.apsf.org/article/how-can-we-tell-how-smart-our-infusion-pumps-are/

          Borrelli EP, Lucaci JD, Wilson NS, Taneja A, Weiss M, Beer I. Evaluating the Impact of Smart Infusion Pump Interoperability on Reducing Medication Administration Errors: A Systematic Literature Review. Med Devices (Auckl). 2025;18:247-60. https://doi.org/10.2147/MDER.S522534

          Giuliano KK, Mahuren RS, Balyeat J. Data-based program management of system-wide IV smart pump integration. American Journal of Health-System Pharmacy. 2024;81(1):e30-6. https://doi.org/10.1093/ajhp/zxad245

          Institute for Safe Medication Practices (ISMP). Guidelines for Optimizing Safe Implementation and Use of Smart Infusion Pumps. ISMP. [Internet] 2020 [Cited 2025 August 01]. Available from: https://home.ecri.org/blogs/ismp-resources/guidelines-for-optimizing-safe-implementation-and-use-of-smart-infusion-pumps

          Joint Commission. Sentinel Event Alert 63: Optimizing smart infusion pump safety with DERS [Internet]. 2021. [Cited 2025 August 01]. Available from: https://www.jointcommission.org/en-us/knowledge-library/newsletters/sentinel-event-alert/issue-63

          Shah N, Jani Y. Implementation of Smart Infusion Pumps: A Scoping Review and Case Study Discussion of the Evidence of the Role of the Pharmacist. Pharmacy. 2020;8(4):239. https://doi.org/10.3390/pharmacy8040239

          Alamer F, Alanazi AT. The Impact of Smart Pump Technology in the Healthcare System: A Scope Review. Cureus. 2023;15(3):e36007. https://doi.org/10.7759/cureus.36007

          Olson C, Bouchard C. Optimizing the Smart Pump Drug Library Update Process: An Ongoing Effort at an Academic Medical Center. Patient Safety. 2024;6(1). https://doi.org/10.33940/001c.123222

          Herrero L, Cano M, Ratwani R, Sánchez L, Sánchez B, Sancibrián R, et al. A review of human factors and infusion pumps: lessons for procurement. Front Digit Health. 2025;7:1425409. https://doi.org/10.3389/fdgth.2025.1425409

          Kuitunen S, Airaksinen M, Holmström AR. Evolution of Intravenous Medication Errors and Preventive Systemic Defenses in Hospital Settings—A Narrative Review of Recent Evidence. Journal of Patient Safety. 2024;20(4):e29-39. https://doi.org/10.1097/PTS.0000000000001222

          Agency for Healthcare Research and Quality, Rockville, MD. Making Health Care Safer II: An Updated Critical Analysis of the Evidence for Patient Safety Practices. [Internet] 2023 [Cited 2025 August 01]. Available from: URL https://www.ahrq.gov/research/findings/evidence-based-reports/ptsafetyuptp.html

          Schnock KO, Dykes PC, Albert J, Ariosto D, Call R, Cameron C, et al. The frequency of intravenous medication administration errors related to smart infusion pumps: a multihospital observational study. BMJ Quality & Safety. 2017;26(2):131-40. https://doi.org/10.1136/bmjqs-2015-004465

          Kuitunen S, Kärkkäinen K, Linden-Lahti C, Schepel L, Holmström AR. Dose error reduction software in medication safety risk management – optimising the smart infusion pump dosing limits in neonatal intensive care unit prior to implementation. BMC Pediatr. 2022;22(1):118. https://doi.org/10.1186/s12887-022-03183-8

          López-Romero LA, Cáceres Rivera DI, Dueñas Badillo RE, Acosta-Barón JV, Robles Méndez IY, Rincón Castillo D, et al. Adherencia y potenciales eventos adversos prevenidos durante la administración de medicamentos endovenosos empleando bombas de infusión inteligentes en cuatro unidades de cuidados intensivos en Colombia. Rev Univ Ind Santander Salud. 2019;51(4):289-300. https://doi.org/10.18273/revsal.v51n4-2019002

          Narváez-Martínez MA, Rosas-Santana A, Rojas-Castañeda YA, Zapata-Cristancho DC. Master Dataset: Monitoring smart infusion pumps in adult intensive care units. Mendeley Data. 2025. https://doi.org/10.17632/f2mdstz6xz.1

          Carrington-Hahn S, Gosselin T, Frasure III E, Reynolds SS. Smart pump technology and dose error reduction. American Nurse Journal. 2025;20(01):33-6. https://doi.org/10.51256/ANJ012533

          Sutherland A, Gerrard WS, Patel A, Randall M, Weston E. The impact of drug error reduction software on preventing harmful adverse drug events in England: a retrospective database study. BMJ Open Quality. 2022;11(3):1-9. https://doi.org/10.1136/bmjoq-2021-001708

          Skog J, Rafie S, Schnock KO, Yoon C, Lipsitz S, Lew P. The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study. Journal Patient Safety. 2022;18(3):e666-71. https://doi.org/10.1097/PTS.0000000000000905

          Ibarra-Pérez R, Puértolas-Balint F, Lozano-Cruz E, Zamora-Gómez SE, Castro-Pastrana LI. Intravenous Administration Errors Intercepted by Smart Infusion Technology in an Adult Intensive Care Unit. Journal Patient Safety. 2021;17(6):430-6. https://doi.org/10.1097/PTS.0000000000000374

          Heron C. Implementing smart infusion pumps with dose-error reduction software: real-world experiences. British Journal of Nursing. 2017;26(8):S13-6. https://doi.org/10.12968/bjon.2017.26.8.S13

          Gray J, Ruggia-Check C, Mentzer L, Finn J, Frezghi F, Riesen A, et al. 1247: Impact of implementation of smart pump interoperability and drug library optimization. Critical Care Medicine. 2024;52(1):S595-S595. . https://doi.org/10.1097/01.ccm.0001003152.59872.b4

          Chin K, Donovan J, Bingham G, Poole S, Tong E. Evaluation of Smart Pump Interoperability with an Electronic Medical Record System to Improve Infusion Safety. IOS Press; 2024:1341-1342. https://doi.org/10.3233/SHTI231185

          Sowan A, Ha B. Maximizing the impact of smart pump-EHR interoperability in critical care. Intensive Crit Care Nurs. 2024;85:103809. . https://doi.org/10.1016/j.iccn.2024.103809

          VanHorn T, Harris J, Mayes S, Infanti LM, Kennedy A. Evaluation of the Effect of Smart Pump Interoperability on Infusion Errors in the Pediatric Hospital Setting. J Pediatr Pharmacol Ther. 2024;29(3):323-30. https://doi.org/10.5863/1551-6776-29.3.323

          Publicado

          2026-04-21

          Como Citar

          1.
          Narváez-Martínez MA, Rosas-Santana A, Rojas-Castañeda YA, Zapata-Cristancho DC. Monitoramento inteligente de bombas de infusão em unidades de terapia intensiva para adultos. Revista Cuidarte [Internet]. 21º de abril de 2026 [citado 26º de abril de 2026];17(1). Disponível em: https://revistas.udes.edu.co/cuidarte/article/view/5160

          Downloads

          Os dados de download ainda não estão disponíveis.